Products |
|
|
|
| Fixed tube construction heat exchangers with NPT connections. Made of brass with copper cooling tubes and cast iron end bonnets. Standard sizes from 2"through 8" diameters, and from 1.4 to 308 sq.ft. Standard one, two, and four pass models are available. Options include 90/10 copper nickel and 316 stainless steel cooling tubes, bonnets and zinc anodes. Can be customized to fit your requirements. Optional 10 " diameter units are available upon request. | Similar to AB series with the exception of the shell ports. SAE series from 2 "through 6 "diameter has SAE O-ring strait thread shell port connections. Size 8 "diameter has SAE code 61 four bolt flange shell port connections. | Similar in design to AB series with fixed tube construction and NPT connections made of all 316 stainless steel. Standard sizes from 2"through 8"diameters,and from 1.4 to 308 sq.ft. Standard one, two and four pass models are available. Larger diameters available upon request. Can be customized to fit your requirements. |
|
| |
Expansion bellow minimizes the effects of differential expansion and contraction between the shell and cooling tubing, prolonging the overall life of the heat exchanger by reducing fatigue. Fixed tube construction heat exchangers with NPT connections. Made of brass with 90/10 copper nickel cooling tubes, stainless steel expansion bellows, and cast iron end bonnets. Standard sizes from 3.5"through 8"diameters,and from 3.6 to 308 sq.ft. Standard one, two and four pass models are available. | Fixed tube construction heat exchangers. Made of carbon steel shell, tube-sheets, baffles, copper tubing, and cast iron end bonnets. 10" diameter with sizes from 194 to 540 sq.ft. Standard one, two or four pass models are available. Rated 300PSI shell side, 150PSI tube side, at 300 f. Options include 90/10 copper nickel, 316L stainless steel, and carbon steel tube, bronze bonnets, and zinc anodes. Can be modified to fit your requirements. Suitable for most hydraulic oils, lubricating oils, heat transfer oils, synthetic compressor oils, phosphate ester, glycols, and any additional fluids compatible with materials of construction. Common applications include engine jacket-water, lubrication systems, hydraulic systems, paper machinery, oil field, off shore equipment, etc |
|
|
|
Fixed tube construction heat exchangers with NPT connections. Made of brass with copper cooling tubes and cast iron end bonnets. and from 1.3 to 200 sq.ft. Standard one, two, and four pass models are available.316 stainless steel cooling tubes, anodes. Can be customized to fit your requirements. Optional 10 ”diameter units in brass are available upon request. | Similar in design to AA series with fixed tube construction and NPT connections made of all 316 stainless steel. Standard sizes from 2 ”through 8 ”diameters. From 1.3 to 200 sq.ft. Standard one, two and four pass models are available. Larger diameters available upon request. Can be customized to fit your requirements. | Standard sizes from 2"through 8"diameters, Options include 90/10 copper nickel and bronze end bonnets and zinc Similar to AA series with the exception of shell ports. FBF series offered from 5 ” through 8 ” diameter has SAE code 61 four bolt flange shell port connections. Available with single pass, two pass, and four pass end bonnets. Options include 90/10 copper nickel and 316 stainless steel cooling tubes, bronze end bonnets, and zinc anodes. In applications where shell fluid is non-corrosive with steel, SFBF series can be used. |
|
| |
Fixed tube construction heat exchangers with NPT connections. Made of steel with copper cooling tubes and cast iron end bonnets. Standard sizes from 3 ”through 8 ” diameters. Standard one, two, and four pass models are available. Options include 90/10 copper nickel and 316 stainless steel cooling tube, and zinc anodes. Can be customized to fit your requirements. | Similar in design to CS series with fixed tube construction and NPT connections made of 316 stainless steel. Standard sizes from 3 ” through 8 ” diameters. Standard one, two, and four pass models are available. Larger diameter units available upon request. Can be customized to fit your requirements. | Fixed tube construction heat exchanger with NPT or SAE shell ports. Welded construction made of carbon steel shell, tube-sheets, baffles, copper tubes, and cast iron end bonnets. Sizes from 2.5 to 5 diameters, and from 2.0 to 47 sq. ft. Standard one or two pass units available. Offered as a dimensional and thermal replacement to many disposable type extended surface type tube and fin shell & tube heat exchangers. Rated 500 PSI shell side, 150PSI tube side, at 300°F. |
| ![]() | |
| CK SERIES | ||
U-tube heat exchangers with removable tube bundle for steam service or for fluids with high differential inlet temperatures. Normally applied when the differential temperature between the hot fluid entering and the cooling fluid entering is 150f or greater. U-tube design allows tubing to freely expand and contract independently of the shell. Welded outer shell construction made of carbon steel. Removable tube bundle comprised of carbon steel tube-sheet and baffles, copper tubes, and cast iron end bonnets. Sizes from 3 to 10 diameters, and from 3.6 to 370 sq. ft. Standard two and four pass units available. Rated 150psi shell, 125psi tubes at 400°F. Optional 90/10 copper-nickel, 316L stainless steel, and carbon steel tube. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic heating oils, phosphate ester, ethylene glycol, and other fluids compatible with listed materials. | Straight-tube heat exchangers with removable tube bundle for steam service or for fluids with high differential inlet temperatures. Normally applied when the differential temperature between the hot fluid entering and the cooling fluid entering is 150f or greater. U-tube design allows tubing to freely expand and contract independently of the shell. Welded outer shell construction made of carbon steel. Removable tube bundle comprised of carbon steel tube-sheet and baffles, copper tubes, and cast iron end bonnets. Sizes from 3 to 10 diameters, and from 3.6 to 370 sq. ft. Standard one and two or pass units available. Rated 150psi shell, 125psi tubes at 400°F. Optional 90/10 copper-nickel, 316L stainless steel, and carbon steel tube. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic heating oils, phosphate ester, ethylene glycol, and other fluids compatible with listed materials. | Fixed tube construction heat exchanger with NPT or SAE shell ports. Welded construction made of carbon steel shell, tube-sheets, baffles, copper tubes, and cast iron end bonnets. Sizes from 2.5” to 5” diameters, and from 2.0 to 47 sq. ft. Standard one or two pass units available. Offered as a dimensional and thermal replacement to many disposable type extended surface type tube and fin shell & tube heat exchangers. Rated 500 PSI shell side, 150PSI tube side, at 300°F. |
| ||
| WATER VALVES | ||
| The type 56-T valve gives smooth regulation of water and other fluids. It's designed for the most rugged application. For example: hydraulic power packaging equipment, hydraulic presses, plastic molding equipment, and anywhere reliability in temperature control is demanded. The type 56-t valve is a better-designed product that won't leak or chatter. To insure dependability, every valve is factory tested three times in different temperature baths. Extra performance can be expected of the bellows also. They are direct acting with sturdy walls, and the inner spring is zinc coated. The seat beads are stainless steel to resist the erosive effects of wire drawing and provide longer life for your needs. Additional features include mounting in any position, Buna-N seat disc, and manual flushing. |
| ||
| Industrial air-cooled oil coolers, standard duty three row brazed tube industrial series heat exchangers with washable internal filter located between the fan and core, direct electric drive cooling fan, OSHA guard, and air directing louvers. Washable filter helps prevent airborne dust and debris from collecting on the core fins for continued optimum performance. Filter can be easily removed within minutes from the filter track, cleaned, and replaced for continued service. Rated operating temperature of 400 °F at 300 PSIG. Thermal capacity up to 100 hp (75Kw).Optional built-in bypass relief valve 30 PSI or 65 PSI. Can be modified to meet your requirements. The ACF series can be used in environments such as Sawmills or foundries, etc...where excessive airborne dust or debris may be present. | Industrial air-cooled oil coolers, standard duty three row brazed tube industrial series heat exchangers with direct electric drive cooling fan, OSHA guard, and air directing louvers. Rated operating temperature of 400 °F at 300 PSIG. Services standard flow rates from 2 to 120 GPM. Thermal capacity up to 100 hp (75Kw).NPT, flange, or SAE straight thread port connections. Optional built-in bypass relief valve 30 PSI or 65 PSI. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrications oils, synthetic compressor oils, phosphate ester, ethylene glycol, and many other fluids compatible with listed material. | Industrial air-cooled oil coolers, standard duty three row brazed tube industrial series heat exchangers with hydraulic drive cooling fan, OSHA guard, and air directing louvers. Rated operating temperature of 400 o F at 300 PSIG. Services standard flow rates from 2 to 120 GPM. Thermal capacity up to 100 hp (75Kw).NPT,flange,or SAE straight thread port connections. Optional built-in bypass relief valve 30 PSI or 65 PSI. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrications oils, synthetic compressor oils, phosphate ester, ethylene glycol, and many other fluids compatible with listed material. |
|
| |
| AOCS SERIES: | ||
| Industrial air-cooled oil coolers, high performance six row rolled or brazed tube industrial series heat exchangers with direct electric drive cooling fan, OSHA guard, and air directing louvers. Rated operating temperature of 400 °F at 300 PSIG. Services standard flow rates from 4 to 250 GPM. Thermal capacity up to 210 hp (157Kw).NPT,flange,or SAE straight thread port connections. Optional built-in bypass relief valve 30 PSI or 65 PSI. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrications oils, synthetic compressor oils, ethylene glycol, and many other fluids compatible with listed material. | Industrial air-cooled oil coolers with hydraulic fan drive, high performance six row rolled or brazed tube industrial series heat exchangers with direct electric drive cooling fan, OSHA guard and air directing louvers. Rated operating temperature of 400 °F at 300 PSIG. Services standard flow rates from 4 to 250 GPM. Thermal capacity up to 210 hp (157Kw). NPT, flange, or SAE straight thread port connections. Optional built-in bypass relief valve 30 PSI or 65 PSI. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrications oils, synthetic compressor oils, ethylene glycol, and many other fluids compatible with listed material. | Severe duty air-cooled oil coolers, super capacity, rolled tube industrial series heat exchangers with direct electric drive cooling fan, OSHA guard, and heavy duty front screen. Rated operating temperature of 300 o F at 200 PSIG. Standard flow rates from 10 to 600 GPM. NPT, ANSI flange, or SAE code 61 four bolt flange port connections. Optional built-in bypass relief valve 30 PSI or 65 PSI. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrications oils, synthetic compressor oils, ethylene glycol, and many other fluids compatible with listed material. |
|
|
|
Compact air-cooled oil coolers designed for small heat removal requirements. Light duty brazed industrial series heat exchangers with direct 1/40hp 115VAC electric drive motor, cooling fan, and protective coil guard. Rated operating temperature of 400°f at 300 PSIG. Services standard flow rates from 0.9 to 30 GPM. Thermal capacity up to 4 hp (3Kw). NPT or SAE straight thread port connections. Made of carbon steel cabinet, manifolds, connections, copper tubes, aluminum fins. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic compressor oils, phosphate ester, ethylene glycol, and many other fluids compatible with listed materials Commonly used for CNC machining centers, presses, hydraulic case drains, lubrications systems, etc | Compact air-cooled oil coolers made to adapt to the fan side of a totally enclosed fan cooled (TEFC) electric motor. Light duty brazed industrial series heat exchangers use airflow generated by the TEFC motor to cool the oil. Unit supplied with properly cut hole for NEMA motor frame sizes of 48-184, adjustable mounting feet, and coil guard included. Rated operating temperature of 400°f at 300 PSIG. Services standard flow rates from 0.2 to 30 GPM. Thermal capacity up to 1.0 hp (.75Kw). NPT or SAE straight thread port connections. Made of carbon steel cabinet, manifolds, connections, copper tubes, aluminum fins. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic compressor oils, phosphate ester, ethylene glycol, and many other fluids compatible with listed materials Commonly used for CNC machining centers, presses, hydraulic case drain lines, small hydraulic power units, etc | Compact air-cooled oil coolers made to adapt to the fan side of a totally enclosed fan cooled (TEFC) electric motor. Light duty brazed industrial series heat exchangers use airflow generated by the TEFC motor to cool the oil. Unit supplied with properly cut hole for NEMA motor frame sizes of 213-365, adjustable mounting feet, and coil guard included. Rated operating temperature of 400°f at 300 PSIG. Services standard flow rates from 0.5 to 40 GPM. Thermal capacity up to 3.6 hp (2.7Kw). NPT or SAE straight thread port connections. Made of carbon steel cabinet, manifolds, connections, copper tubes, aluminum fins. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic compressor oils, phosphate ester, ethylene glycol, and many other fluids compatible with listed materials Commonly used for CNC machining centers, presses, hydraulic case drain lines, small hydraulic power units, etc |
|
|
Mobile air-cooled Oil coolers. Brazed core mobile series heat exchangers designed to be placed into an air stream. Normally applied in front of a radiator or anywhere where a source of air is available. Rated operating temperature of 400°f at 300 PSIG. Services standard flow rates from 2 to 100 GPM. Thermal capacity up to 70 hp (52Kw). NPT or SAE straight thread O-ring port connections. AOMR offered with optional built-in bypass relief valve 30PSI or 65PSI. Made of carbon steel manifolds, connections, copper tubes, aluminum fins. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic compressor oils, phosphate ester, ethylene glycol, and many other fluids compatible with listed materials. Cools transmissions, hydraulic systems, jacket water, etc | Industrial air-cooled Air coolers. Brazed and serviceable coreâ industrial series air heat exchangers features direct electric drive cooling fan, OSHA guard, and core guard. Rated operating temperature of 400°f at 150 PSIG. Services standard flow rates from 5 to 2800 SCFM. Standard thermal capacity to 120 hp (90Kw). NPT or ANSI flange port connections. Made of carbon steel cabinet, manifolds, connections, copper tubes, aluminum fins. Can be modified to meet your requirements. Suitable for air, nitrogen, water, and many other gases or vapors compatible with listed materials. Can be modified to meet your requirements. Cools remediation blowers, steam systems, compressors, vapor recovery, etc . |
|
|
|
Mobile air-cooled oil coolers. Standard duty brazed mobile series heat exchangers with direct 12volt DC (9amp) or 24volt DC (4.5amp) motor with cooling fan. Rated operating temperature of 400°f at 300 PSIG. Services standard flow rates 80 GPM. Thermal capacity up to 34 hp (25Kw) based upon a 100°f ETD. NPT or SAE straight thread O-ring port connections. Optional built-in bypass relief valve 30PSI or 65PSI. Made of carbon steel cabinet, manifolds, connections, copper tubes, aluminum fins. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic compressor oils, phosphate ester, ethylene glycol, and many other fluids compatible with listed materials. | Low profile mobile air-cooled oil coolers. Standard duty brazed mobile series heat exchangers with direct 12volt DC (9.5amp) or 24volt DC (4.75amp) motor with cooling fan, and protective cabinet. Rated operating temperature of 400°f at 300 PSIG. Services standard flow rates 150 GPM. Thermal capacity up to 32 hp (24Kw) based upon a 100°f ETD. NPT or SAE straight thread O-ring port connections. Optional built-in bypass relief valve 30PSI or 65PSI. Made of carbon steel cabinet, manifolds, connections, copper tubes, aluminum fins. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic compressor oils, phosphate ester, ethylene glycol, and many other fluids compatible with listed materials. | Mobile &industrial air-cooled oil coolers. Brazed or serviceable core ®,mobile and industrial series heat exchangers available with optional washable filter and integral relief valve,30 PSI or 65 PSI. Standard single phase, three phase,12 volt DC (21amp)or 24 volt DC (10.5 amp) motors with single or dual cooling fans. Rated operating temperature of 400 o F at 300 PSIG. Standard flow rates to 180 GPM. Thermal capacity up to 225 hp (168 Kw). NPT or SAE strait thread O-ring port connections. Can be modified to meet your requirements. Suitable for most hydraulic oils, lubrication oils, synthetic compressor oils, ethylene glycol, and many other fluids compatible with listed materials. |
| ||
| ELECTRICAL TEMPERATURE CONTROLLER | ||
| The TC511 temperature controller is designed to control motor/fan run time to create stable operating temperature of air or liquids in ducts, pipes, tanks, and boilers. Typical uses include control of dampers and valves in heating, cooling, or heating-cooling systems. The TC511 has 1 spdt switch. It makes or breaks a circuit on a change in temperature at the sensing bulb. Fast response models with adjustable differential are available for duct installation. They respond approximately 4 times faster than standard models. No external power source is required to operate the TC511 controller. |